T: +44 1274 750 620

E: sales@ndmeter.co.uk

8am - 4:30pm Monday - Friday UK

< Rail Mounted Meters
< Panel Mounted Meters Rail 350
Rail 350 Data Sheet
Download PDF
Rail 350
Standard Features Model Options
• 3Ø energy & power sub-meter • Standard 6-way DIN-rail mount • Pulse Output, MODBUS & Ethernet Comms options •Measures comprehensive range of energy and power parameters •Easy-fit auto-CT rotation •5/1Amp & mV retrofit CT input options •Voltage balance mode •Custom wall mount enclosure •Hours run •5 year warranty •CE, UL, C-Tick accredited Pulse Output Option •kWh & kVArh over 2 Pulse Outputs •Comprehensive range of energy & power parameters on the display MODBUS RS485 Option •2 pulse outputs •Comprehensive range of energy & power parameters over MODBUS & smaller selection on display •Individual harmonics to the 15th, THD to the 30th over MODBUS option IP Ethernet Option •Web pages show energy, power, volts, amps, power factor, & digital input/output set-up •Log upto 60 parameters •Set up logging for FTP / HTTP / TFTP / SNMP for directly interfacing with energy management software & building control solutions •3 scalable Digital Pulse Inputs can measure other utilities eg gas & water etc •2 digital alarm outputs •Individual Harmonics to the 15th, THD to the 30th over MODBUS TCP/IP standard •Comprehensive range of energy & power parameters over IP Ethernet & smaller selection on display
Features
Don’t let the simple looks of the Rail 350 fool you, this is a powerful, feature rich multifunction meter. The Rail 350’s ‘Right First Time’ setup includes the Auto-rotation functionality for CTs which may be installed incorrectly. This effort to minimize and correct any installation issues, married to the 5 year warranty and extensive data sets available via the communication options makes this the perfect system meter for any sub-metering roll-out. Standard feature on the Rail 350 is 2 pulse outputs, which can be configured for kWh and kvarh. To aid with installation and commissioning the meter offers a pulse test function to simulate pulses without any load being measured, allowing installation engineers to check cabling is complete. Standard communications are RS485 Modbus, however the Rail 350 is available with a range of powerful IP communications options MODBUS TCP and other TCP/IP protocols such as HTTP, FTP, TFTP, SNMP. The various TCP/IP protocols make this the ideal meter to interface directly with energy management software and building control solutions, without the need for data loggers or concentrators. The web pages on the IP enabled Rail 350 allows the user to view important instantaneous values and access the setup pages should the need arise to change any of the parameters. Technical Specifications
Multi-Parameter Available via Display & MODBUS
All Phases System
Volts, L-N & L-L Amps Power Factor Import kWh, kVArh Hours run (on load) Inductive and capacitive kVArh Peak Volts, L-N Peak Amps Neutral Amps kW, kVA & kVAr kW, kVA & kVAr Demand Peak kW, kVA, & kVAr Demand Average Volt & Peak Amp, Demand & Peak Export kWh, kVArh • kW Frequency
• • • • • • • • • • • • • • • • • (Option) % THD Volts & Amps Individual Harmonics 2nd - 15th • •
True RMS measurement of Volts & Amps - and true Power Measurement - to the 30th Harmonic at 50Hz (>25th@60Hz)
Accreditations: CB, CE, UL, C-Tick Warranty: ND Metering 5 Year Warranty
INPUTS: System: 3 Ø 3 or 4 Wire Unbalanced Load Voltage: 480/277V Current I: 5Amp, 1 Amp or 0.333V Measurement Range: Voltage 20% to 120% Current 0.2% to 120% Frequency Range: Fundamental 45 to 65 Hz -Options With Comms: Harmonics THD to 30th Harmonic at 50Hz -Options With Comms: Individual Harmonics to 15th AUXILIARY SUPPLY: 230V 50/60Hz at 5W max 110V 50/60Hz at 5W max ACCURACY kWh: Class 1 per EN 62053-21 & BS 8431 ANSI C12.20 Class 0.5 kvarh: Class 2 per EN 62053-23 & BS 8431 kW & kVA: Class 0.25 IEC 60688 kvar: Class 0.5 IEC 60688 Amps & Volts: Class 0.1 IEC 60688 Power Factor: ±0.2° Neutral Current: Class 0.5 IEC 60688 PULSE OUTPUTS Function: 1 pulse per unit of energy Scaling: Configurable Pulse Duration: 0.1 second default (other durations configurable) Type: N/O volt free contact. Optically isolated Contacts: 100mA ac/dc max; 70Vdc/33Vac max; 5W max. load Isolation: 3.5 kV 50Hz 1 minute GENERAL Operating: -10º to +55ºC Storage: -25ºC to + 70ºC Humidity: <75% non-condensing Environment: IP20 MECHANICAL Terminals: Rising Cage. 4mm2 (AWG) cable max Enclosure: DIN 43880, 6 modules wide Material: Noryl® with fire protection to UL94-V-O. Self extinguishing Dimensions: 106X90X58mm (4.2”x3.5”x2.3”) Weight: 150gms (0.33lbs)
Site Products Contact
Home About Contact
Rail Mounted Meters Panel Mounted Meters Wall Mounted Meters
MMU's Currents Transformers Transducers
Clamp On Current Transformers
+44 1274 750 620 sales@ndmeter.co.uk 8am - 4:30pm Monday - Friday